{"product_id":"oxyair-2-0-ata-hard-shell-sitting-hyperbaric-chamber-two-people","title":"OxyAir OLV-YZM02 — 2.0 ATA Two-Person Hard-Shell Sitting Hyperbaric Chamber","description":"\u003cp\u003eOxyAir's two-person 2.0 ATA seated chamber is a modular hard-shell system with an aluminum-alloy cabin, two reclining seats, oxygen supply modules and an air booster. OxyAir's primary technical table identifies the chamber as OLV-YZM02.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwo-person cabin with dual seating and panoramic viewing.\u003c\/li\u003e\n\u003cli\u003eManufacturer lists integrated Built-In Breathing System (BIBS), intercom, interior\/exterior control interfaces and pressure-relief systems.\u003c\/li\u003e\n\u003cli\u003eManufacturer describes a dual oxygen-supply arrangement, air compressor and separate air-conditioning module.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer technical model\u003c\/th\u003e\n\u003ctd\u003eOLV-YZM02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChamber type\u003c\/th\u003e\n\u003ctd\u003eHard shell; two-person sitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking pressure\u003c\/th\u003e\n\u003ctd\u003e2.0 ATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChamber dimensions\u003c\/th\u003e\n\u003ctd\u003e2230 × 1900 × 1970 mm (L × W × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer-listed chamber weight\u003c\/th\u003e\n\u003ctd\u003e750 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChamber construction\u003c\/th\u003e\n\u003ctd\u003eAluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDoor thickness\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChamber power\u003c\/th\u003e\n\u003ctd\u003e200 W (chamber module only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply options\u003c\/th\u003e\n\u003ctd\u003e110\/240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOxygen modules\u003c\/th\u003e\n\u003ctd\u003e2 × 20 L\/min oxygen concentrator output; 93% ±3% purity (manufacturer-stated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir booster\u003c\/th\u003e\n\u003ctd\u003e400 L\/min class; manufacturer lists 3100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eComfort and controls\u003c\/th\u003e\n\u003ctd\u003eDual sofa; 43-inch TV; intercom; interior\/exterior controls; air-conditioning module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eEquipment and configuration\u003c\/h3\u003e\u003cp\u003eThe manufacturer's chamber composition describes the chamber, two oxygen concentrators, a separate compressor and air-conditioning. A dealer lists the two sets of BIBS masks and a dual-seat sofa. Confirm voltage and included components in the order-specific bill of materials.\u003c\/p\u003e\u003ch3\u003ePlanning and installation\u003c\/h3\u003e\u003cp\u003eCheck the chamber's installed footprint, entry clearance, floor loading, suitable power supply, ventilation, user supervision and operator training before selecting a configuration. Delivery method, installation scope and site requirements are confirmed for each order. Published dealer lead times and bundles may differ from the actual SimWellness offer.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eCan two people use the system simultaneously?\u003c\/strong\u003e The manufacturer specifies a dual-seat chamber.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat footprint should be planned?\u003c\/strong\u003e Start from the manufacturer-listed chamber dimensions plus separately positioned concentrators, air booster, air conditioner, door swing\/access and service clearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs its model number YZM01 or YZM02?\u003c\/strong\u003e OxyAir's technical specification calls it OLV-YZM02, while Morelli Medical's title calls a similar unit OLV-YZM01. The exact unit supplied must be reconciled before order.\u003c\/p\u003e\u003ch3\u003eModel verification\u003c\/h3\u003e\u003cp\u003eManufacturer specification identifies OLV-YZM02; a competing dealer names OLV-YZM01 in its title and uses OLV-YZM02 in its table. These are not assumed to be interchangeable.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAvailability:\u003c\/strong\u003e This listing is under specification and U.S. regulatory review. Final equipment, warranty, shipment terms and U.S. market eligibility must be verified before purchase. No FDA clearance is claimed for this model.\u003c\/p\u003e\u003ch3\u003eShipping and delivery\u003c\/h3\u003e\u003cp\u003eEstimated delivery to U.S. addresses is approximately \u003cstrong\u003e30–40 days\u003c\/strong\u003e using the supplier's door-to-door delivery service. This is an estimate, not a guaranteed arrival date; timing and delivery access requirements will be confirmed for each order. Under the supplier's stated U.S. door-to-door arrangement, the shipping agent manages import clearance and applicable import duties and taxes, so customers are not expected to arrange customs formalities or pay a separate import-duty bill. Confirm the complete delivered quotation and destination eligibility before purchase. On-site placement, electrical work, commissioning and installation are not included unless specifically agreed in writing.\u003c\/p\u003e\u003ch3\u003eManufacturer warranty and after-sales support\u003c\/h3\u003e\u003cp\u003eOxyAir offers a \u003cstrong\u003e2-year manufacturer warranty\u003c\/strong\u003e and \u003cstrong\u003elifetime technical support\u003c\/strong\u003e, subject to the manufacturer's written warranty terms. If a fault develops, contact SimWellness with a description and a short video so the manufacturer's technical team can review the problem. Troubleshooting starts remotely and may involve checking connections, settings, tubing, valves, sensors or other serviceable modules. If a spare part is required, OxyAir says it can normally arrange the part within \u003cstrong\u003e3–5 working days\u003c\/strong\u003e, followed by international express shipping; this is the usual arrangement period, not a delivery guarantee. Replacement parts for failures covered under warranty are supplied without a parts charge according to the warranty terms. After warranty expiry, spare parts are chargeable, while technical troubleshooting, replacement instructions and remote video assistance remain available.\u003c\/p\u003e\u003ch3\u003eU.S. regulatory status\u003c\/h3\u003e\u003cp\u003eThis OxyAir model is \u003cstrong\u003enot FDA cleared\u003c\/strong\u003e according to the manufacturer. Its regulatory status and eligibility for sale, import and intended use in the United States require confirmation before orders can be accepted. The chamber must not be represented as FDA approved or promoted for treatment of a medical condition without the applicable authorizations and substantiation.\u003c\/p\u003e","brand":"OxyAir","offers":[{"title":"Default Title","offer_id":55294723719505,"sku":null,"price":93999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0935\/6738\/5937\/files\/oxyair-hard-shell-two-seater-2ata.png?v=1791934587","url":"https:\/\/www.simgolfer.com\/products\/oxyair-2-0-ata-hard-shell-sitting-hyperbaric-chamber-two-people","provider":"Sim Golfer","version":"1.0","type":"link"}